JSLHR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Speech and Hearing Research Vol.39 261-277 April 1996.
© American Speech-Language-Hearing Association

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parkinson, A. J.
Right arrow Articles by Gantz, B. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parkinson, A. J.
Right arrow Articles by Gantz, B. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

A Within-Subject Comparison of Adult Patients Using the Nucleus F0F1F2 and F0F1F2B3B4B5 Speech Processing Strategies

Aaron J. Parkinson 1
Richard S. Tyler 2
George G. Woodworth 3
Mary W. Lowder 1

Bruce J. Gantz 1

1 Department of Otolaryngology—Head and Neck Surgery University of Iowa Iowa City
2 Department of Otolaryngology—Head and Neck Surgery and Department of Speech Pathology and Audiology University of Iowa Iowa City
3 Department of Statistics and Actuarial Sciences University of Iowa Iowa City

This study compares the Nucleus F0F1F2 and F0F1F2B3B4B5 (also known as "Multipeak" or "Mpeak") processing schemes in 17 patients wearing the Mini Speech Processor. All patients had at least 18 months implant experience using the F0F1F2 processing strategy. For this study, they were switched to the F0F1F2B3B4B5 processing strategy for 3 months. They then returned to using the F0F1F2 strategy for 3 months, then used the F0F1F2B3B4B5 strategy again for 3 months, and lastly used the F0F1F2 strategy for 3 months. Performance was evaluated with both schemes after each interval, using speech recognition tests and subjective ratings. Overall, differences between the results for the two processing schemes were not large. Average performance was somewhat better for the F0F1F2B3B4B5 strategy for word and sentence identification, but not for any of the other speech measures. Superior performance was observed in 8 patients with the F0F1F2B3B4B5 strategy. However, 6 of the 8 individuals were significantly better on only one of the six speech measures in the test battery. The other 2 patients performed better on two of the speech measures. Superior performance was also observed in 3 patients with the F0F1F2 strategy for consonant recognition. For the remaining patients, there was little difference in their performance with the two strategies. Information transmission analyses indicated that the F0F1F2B3B4B5 strategy transmitted consonant duration and frication cues more efficiently than F0F1F2. Experience with one strategy appeared to benefit performance with the other strategy.

KEY WORDS: cochlear implants, speech processing, feature extraction, deafness

Submitted on April 22, 1994
Accepted on November 27, 1995


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
All ASHA Journals AJA AJSLP JSLHR LSHSS
Copyright © 1996 by the American Speech-Language-Hearing Association.