JSLHR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Speech and Hearing Research Vol.35 175-185 February 1992.
© American Speech-Language-Hearing Association

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fortune, T. W.
Right arrow Articles by Preves, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fortune, T. W.
Right arrow Articles by Preves, D. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Hearing Aid Saturation and Aided Loudness Discomfort

Todd W. Fortune 1
David A. Preves 1

1 Argosy Electronics Eden Prairie, MN

Clinical measurements of the loudness discomfort level (LDL) are generally performed while the subject listens to a particular stimulus presented from an audiometer through headphones (AUD-HP). The assumption in clinical practice has been that the sound pressure level (SPL) corresponding to the sensation of loudness discomfort under AUD-HP conditions will be the same as that corresponding to LDL with the hearing aid. This assumption ignores the fact that the distortion produced by a saturating hearing aid could have an influence on the sensation of loudness. To examine these issues, 5 hearing-impaired subjects were each fit with four linear hearing aids, each having a different saturation sound pressure level (SSPL90). Probe-tube microphone measurements of ear canal SPL at LDL were made while the subjects listened to continuous discourse in quiet under aided and AUD-HP conditions. Also using continuous discourse, real-ear coherence measures were made at various output sound pressure levels near LDL. All four hearing aid types produced mean LDLs that were lower than those obtained under AUD-HP conditions. Those hearing aids with higher SSPL90 produced significantly higher LDLs than hearing aids with lower SSPL90. A significant negative correlation was found between real-ear SPL and real-ear coherence. Quality judgments made at LDL indicated that sound quality of hearing aids with higher SSPL90 was preferred to that of hearing aids with lower SSPL90. Possible fitting implications regarding the setting of SSPL90 from AUD-HP LDL measures are discussed.

KEY WORDS: hearing aids, headroom, aided loudness discomfort, saturation, coherence

Submitted on October 31, 1990
Accepted on April 5, 1990


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
All ASHA Journals AJA AJSLP JSLHR LSHSS
Copyright © 1992 by the American Speech-Language-Hearing Association.